Infusion Set Functional Characteristics and Clinical Application Standards Guide

Drip-Chamber-Flow-Rate-Control-Mechanism-Healthcare

The infusion set, as the core medical device for intravenous infusion therapy, plays an irreplaceable role in modern clinical medicine. This document aims to provide healthcare professionals with systematic guidance on the functional characteristics, operational standards, and quality management of infusion sets to ensure patient safety and enhance treatment outcomes.

1. Structural Components and Basic Functions of Infusion Sets

1.1 Standard Structural Components

Standard disposable infusion sets consist of the following core components:

  • Infusion bottle (bag) hook: Supports infusion containers, ensuring stable suspension
  • Drip chamber: Controls fluid flow rate, facilitates flow observation
  • Infusion tubing: Medical-grade PVC material, typically 150-200cm in length
  • Flow rate regulator: Precision control of infusion speed
  • Injection port: Facilitates additional medication injection
  • Precision filter: Filters foreign particles, typically 5μm or 15μm specifications
  • Intravenous needle: Establishes venous access, ranging from 18G to 24G

1.2 Core Functional Characteristics

1.2.1 Precise Flow Rate Control

  • Drop factor standard: International standard of 20 drops/mL (adult use) or 60 drops/mL (pediatric use)
  • Flow rate calculation formula: Infusion rate (mL/h) = Drops per minute × 60 ÷ Drop factor
  • Clinically recommended drop rates:
    • Adult routine infusion: 40-60 drops/minute (120-180mL/h)
    • Pediatric infusion: Calculated at 4-6mL/kg/h based on body weight
    • Elderly patients: Appropriately reduced to 30-40 drops/minute

1.2.2 High-Efficiency Filtration Protection

Modern infusion sets equipped with precision filtration systems can effectively remove:

  • Glass particles (>5μm)
  • Rubber fragments and plastic particles
  • Fibrous foreign matter
  • Certain microbial contaminants

1.2.3 Air Embolism Prevention

  • Drip chamber fluid level control: Maintained at 1/3 to 2/3 of chamber volume
  • Automatic shut-off device: High-end products equipped with automatic stop when fluid is depleted
  • Air-elimination design: Effectively prevents air from entering the blood circulation system
Infusion-Set-Components-Structure-Diagram-Medical-Device

2. Clinical Application Technical Standards

2.1 Sterile Operation Standard Procedures

2.1.1 Pre-use Inspection Points

  1. Package integrity: Check for damage or moisture in packaging
  2. Expiration date confirmation: At least 6 months before expiration
  3. Product identification: Verify batch number, specifications, production date
  4. Visual inspection: Tubing transparency, connection point tightness

2.1.2 Standard Operating Procedures

Pre-operative preparation → Sterile protection → Equipment inspection → 
Establish access → Flow rate setting → Process monitoring → 
Complete care → Record documentation

2.2 Clinical Standards for Flow Rate Control

Patient TypeWeight Range (kg)Recommended Flow Rate (mL/h)Special Considerations
Neonates2.5-4.010-20Strictly calculate by weight
Infants/Toddlers4-1530-80Monitor electrolyte balance
Children15-4080-200Adjust according to condition
Adults>40200-500Assess cardiac/renal function
Elderly>65150-300Reduce infusion speed

2.3 Infusion Reaction Monitoring and Management

2.3.1 Common Adverse Reaction Types

  • Allergic reactions: Rash, dyspnea, hypotension
  • Pyrogenic reactions: Fever, chills, general malaise
  • Phlebitis: Pain along venous pathway, erythema, induration
  • Fluid overload: Pulmonary edema, cardiac dysfunction

2.3.2 Emergency Response Procedures

  1. Immediately stop infusion
  2. Maintain venous access
  3. Monitor vital signs
  4. Provide symptomatic treatment
  5. Detailed documentation and reporting
Precision-Filter-Particle-Removal-System-Medical-Safety

3. Infusion Set Classification and Selection Guide

3.1 Classification by Function

TypeTechnical FeaturesApplication RangePrice Range
Standard TypeBasic filtration, flow controlRoutine drug infusionEconomic
Precision TypeHigh-precision filtration, fine flow controlChemotherapy drugs, blood productsMid-to-High-end
Smart TypeElectronic control, data recordingICU, operating room applicationsHigh-end
Specialized TypeSpecial materials, customized functionsSpecial drugs, sensitive patientsCustomized

3.2 Material Safety Considerations

3.2.1 PVC Material Infusion Sets

  • Advantages: Low cost, good transparency, excellent flexibility
  • Limitations: Contains DEHP plasticizer, may affect certain drug stability
  • Applications: Routine water-soluble drug infusion

3.2.2 Non-PVC Material Infusion Sets

  • Material types: Polyolefin, silicone, polyurethane, etc.
  • Advantages: DEHP-free, better chemical stability
  • Applications: Lipid-soluble drugs, pediatric medications, long-term treatment
Different-Types-Infusion-Sets-Classification-Comparison

4. Quality Control and Risk Management

4.1 Product Quality Standards

4.1.1 National Standard Requirements

  • Implementation standard: GB 8368-2018 “Disposable Infusion Sets”
  • Registration requirements: NMPA registration certificate
  • Quality system: ISO 13485 Medical Device Quality Management System

4.1.2 Performance Indicator Requirements

  • Flow accuracy: Within ±10%
  • Drop factor deviation: Within ±10%
  • Filtration efficiency: ≥99.9% (for corresponding particle size)
  • Biocompatibility: Compliant with ISO 10993 series standards

4.2 Risk Control Measures

4.2.1 Systematic Risk Prevention and Control

Risk TypeOccurrence ProbabilityHarm SeverityControl Measures
Air embolismLowHighStrict air elimination, use anti-embolism devices
Infection transmissionMediumHighSterile operation, single-use only
Drug adverse reactionsMediumMediumAllergy history inquiry, reaction monitoring
Flow rate errorsHighMediumDouble-person verification, electronic monitoring

4.2.2 Complete Quality Traceability

Establish complete traceability chain from production to use:

  • Production phase: Raw material control, process monitoring, finished product inspection
  • Distribution phase: Storage conditions, transportation monitoring, expiration management
  • Usage phase: Usage records, adverse event reporting, effectiveness evaluation
Quality-Control-Risk-Management-Assessment-Matrix

5. Technology Development Trends and Prospects

5.1 Intelligent Development Directions

  • IoT integration: Internet of Things technology for remote monitoring
  • AI assistance: Artificial intelligence optimization of infusion parameters
  • Data management: Seamless integration with electronic medical record systems

5.2 Material Science Advances

  • Enhanced biocompatibility: Application of new biomaterials
  • Functional enhancement: Antimicrobial, anticoagulant special functions
  • Environmental sustainability: Biodegradable material development
 Smart-Infusion-Technology-Future-Development-Trends

6. Conclusions and Recommendations

As a fundamental medical device in clinical treatment, the safety and effectiveness of infusion sets directly relate to patient health and life. Medical institutions should:

  1. Establish standardized operating procedures to ensure all healthcare personnel master correct infusion set usage methods
  2. Improve quality management systems, implementing quality control throughout the procurement-to-use process
  3. Strengthen continuing education and training to enhance healthcare personnel’s professional skills and safety awareness
  4. Advance information management by utilizing modern technology to improve infusion therapy safety and efficiency

Through scientific and standardized use of infusion sets, patient safety can be maximized, treatment outcomes enhanced, and solid support provided for continuous improvement of clinical medical quality.


This guidance document is compiled based on current national standards and international best practices for reference by medical institutions and healthcare personnel. For the latest standard requirements or technical updates, please follow relevant official publications.

Share:

More Posts

Send Us A Message

kohope logo

Kohope Medical has supported many clients around the world for more than 15 years and has been highly recognized by all clients. Kohope hospital medical suppliers are proud of providing you with top quality medical disposable products and outstanding services.

Get In Touch

Address: Room 1001, Building B, No.2888, South Qilianshan Road, Shanghai, 200331, China.

©2025 kohope.com All Rights Reserved.

Get Price

We will contact you within 24 hours.

Please be aware that our official email address has the domain @kohope.com. To avoid potential phishing scams, kindly verify the sender before responding.

Contact Information: